TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 783 of 1760

CONTINUITY TEST CONTINUITY TEST (1) Remove relay K8 from PDP. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to PDP terminal 87, where relay K7 was removed. (4) Connect negative (-) probe of multimeter to PDP terminal 30, where relay K8 was removed and note reading on multimeter. (5) If continuity is not present, repair wire 1417 from PDP relay K7 terminal 87 to PDP relay K8 terminal 30 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (6) Install relay K7 in PDP. (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to relay K8 terminal 87A. (3) Connect negative (-) probe of multimeter to relay K8 terminal 30 and note reading on multimeter. (4) If continuity is not present, replace relay K8 (para 7-9). (5) If continuity is present, replace relay K7 (para 7-9). (6) Install relay K8 in PDP. (7) Install PDP cover (para 16-2). TM 9-2320-365-20-1 Change 1 2-518.1