TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 769 of 1760

TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-505 2-505 2-505 2-505 2-505 CONTINUITY TEST (1) Remove four screws from lighted indicator display. (2) Remove lighted indicator display from instrument panel assembly. (3) Disconnect connector PX7 from lighted indicator display. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to lighted indicator display terminal 27. (6) Connect negative (-) probe of multimeter to lighted indicator display terminal 23 and note reading on multimeter. (7) If continuity is not present, go to step 3 of this fault.