TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 755 of 1760

(1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX7 pin 25. (3) Connect negative (-) probe of multimeter to terminal lug TL156 and note reading on multimeter. (4) If continuity is not present, repair wire 1530 from connector PX7 pin 25 to terminal lug TL156 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). CONTINUITY TEST NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back or not capable of making good contact. Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION Change 1 2-495 TM 9-2320-365-20-1