TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-483 2-483 2-483 2-483 2-483 CONTINUITY TEST (1) Disconnect connector J114 (bottom connector) from WTEC II TEPSS. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to connector J114-5. (4) Connect negative (-) probe of multimeter to connector J118-1 and note reading on multimeter. (5) If continuity is not present, repair wire 105 (para 2-40) or replace WTEC II cab transmission harness (para 7-86). (6) If continuity is present, replace WTEC II TEPSS (para 8-2). (7) Connect connector J114 to WTEC II TEPSS. (8) Connect connector J118 to connector P118. (9) Install instrument panel assembly (para 7-15). (10) Connect lighted indicator display to connector PX7. (11) Position lighted indicator display in instrument panel assembly with four screws. (12) Tighten four screws to 6-10 lb-in. (1 N·m). (13) Connect batteries (para 7-48).