TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-477 2-477 2-477 2-477 2-477 CONTINUITY TEST CONTINUITY TEST (9) Position lighted indicator display in instrument panel assembly with four screws. (10) Tighten four screws to 6-10 lb-in. (1 N·m). (11) Connect batteries (para 7-48). (1) Remove instrument panel assembly for access (para 7-15). (2) Disconnect connector PX1 from radiator fan off switch. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to connector PX7-26. (5) Connect negative (-) probe of multimeter to connector PX1-6 and note reading on multimeter. (6) If continuity is not present, repair wire 1814 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX1-2. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 3023 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (5) If continuity is present, replace radiator fan off switch (para 7-18). (6) Connect connector PX1 to radiator fan off switch. (7) Install instrument panel assembly (para 7-15). (8) Connect lighted indicator display to connector PX7.