TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 735 of 1760
TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-475 2-475 2-475 2-475 2-475 CONTINUITY TEST (1) Loosen four captive screws in lamp mounting panel. (2) Remove lamp mounting panel from lighted indicator display housing. (3) Remove fan off indicator lamps from printed circuit board. (4) Set multimeter to ohms. (5) Check continuity through each fan off indicator lamp and note reading on multimeter. (6) If continuity is not present, replace fan off indicator lamps (para 7-16). (7) If continuity is present, replace lighted indicator display (para 7-16). (8) Install fan off indicator lamps in printed circuit board. (9) Install lamp mounting panel in lighted indicator display housing. (10) Tighten four captive screws in lamp mounting panel. (11) Connect lighted indicator display to connector PX7. (12) Position lighted indicator display in instrument panel assembly with four screws. (13) Tighten four screws to 6-10 lb-in. (1 N·m). (14) Connect batteries (para 7-48).