TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-437 2-437 2-437 2-437 2-437 CONTINUITY TEST (1) Disconnect batteries (para 7-48). (2) Remove PDP cover (para 16-2). (3) Remove three screws and washers from PDP. (4) Remove three screws from PDP. (5) Lift PDP outward to gain access. (6) Connect positive (+) probe of multimeter to TB1 position 41. (7) Connect negative (-) probe of multimeter to TB1 position 42 and note reading on multimeter. (8) If continuity is not present, repair wire 1580 from TB1 position 41 to TB1 position 42 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (9) If continuity is present, repair wire 1580 in dashboard cable assembly (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (10) Install PDP on dashboard with three screws. (11) Install three washers and screws in PDP. (12) Install PDP cover (para 16-2). (13) Connect lighted indicator display to connector PX7. (14) Position lighted indicator display in instrument panel assembly with four screws. (15) Tighten four screws to 6-10 lb-in. (1 N·m). (16) Connect batteries (para 7-48).