TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-431 2-431 2-431 2-431 2-431 CONTINUITY TEST (14) Tighten four screws to 6-10 lb-in. (1 N·m). (1) Loosen four captive screws in lamp mounting panel. (2) Remove lamp mounting panel from lighted indicator display housing. (3) Remove left turn signal indicator lamps from printed circuit board. (4) Set multimeter to ohms. (5) Check continuity through each left turn signal indicator lamp and note reading on multimeter. (6) If continuity is not present, replace lamps (para 7-16). (7) If continuity is present, replace lighted indicator display (para 7-16). (8) Install left turn signal indicator lamps in printed circuit board. (9) Install lamp mounting panel in lighted indicator display housing. (10) Tighten four captive screws in lamp mounting panel. (11) Disconnect batteries (para 7-48). (12) Connect lighted indicator display to connector PX7. (13) Position lighted indicator display in instrument panel assembly with four screws.