TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 687 of 1760

TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-427 2-427 2-427 2-427 2-427 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX7-17. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 3030 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (5) If continuity is present, repair wire 1803 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (6) Connect lighted indicator display to connector PX7. (7) Position lighted indicator display in instrument panel assembly with four screws. (8) Tighten four screws to 6-10 lb-in. (1 N·m). (9) Connect batteries (para 7-48). (1) Loosen four captive screws in lamp mounting panel. (2) Remove lamp mounting panel from lighted indicator display housing. (3) Remove chemical detector indicator lamps from printed circuit board. (4) Set multimeter to ohms. (5) Check continuity through each chemical detector indicator lamp and note reading on multimeter. (6) If continuity is not present, replace lamps (para 7-16). (7) If continuity is present, replace lighted indicator display (para 7-16). (8) Install chemical detector indicator lamps in printed circuit board. (9) Install lamp mounting panel in lighted indicator display housing. (10) Tighten four captive screws in lamp mounting panel. (11) Connect lighted indicator display to connector PX7. (12) Position lighted indicator display in instrument panel assembly with four screws. (13) Tighten four screws to 6-10 lb-in. (1 N·m). (14) Connect batteries (para 7-48).