TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-412 2-412 2-412 2-412 2-412 YES 2. YES 3. Is continuity present between connector PX7-17 and a known good ground? If continuity is not present, wire 3030 is faulty. Is continuity present between relay K52 terminals 30 and 87A? If continuity is not present, relay K52 is faulty. NO NO KNOWN INFO TEST OPTIONS REASON FOR QUESTION Continuity Test or STE/ICE-R #91 CTIS operates normally. Lighted indicator display OK. POSSIBLE PROBLEMS Faulty dashboard cable assembly. Faulty relay K52. Faulty CTIS ECU. Faulty CTIS cable assembly. KNOWN INFO TEST OPTIONS Continuity Test or STE/ICE-R #91 REASON FOR QUESTION CTIS operates normally. Lighted indicator display OK. POSSIBLE PROBLEMS Faulty relay K52. Faulty dashboard cable assembly. Faulty CTIS ECU. Faulty CTIS cable assembly. Repair wire 3030 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). Replace relay K52 (para 7-9). e25. CTIS OVERSPEED INDICATOR DOES NOT OPERATE (CONT) e25. CTIS OVERSPEED INDICATOR DOES NOT OPERATE (CONT) e25. CTIS OVERSPEED INDICATOR DOES NOT OPERATE (CONT) e25. CTIS OVERSPEED INDICATOR DOES NOT OPERATE (CONT) e25. CTIS OVERSPEED INDICATOR DOES NOT OPERATE (CONT)