TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-401 2-401 2-401 2-401 2-401 CONTINUITY TEST CONTINUITY TEST (1) Remove six screws from auxiliary panel. (2) Lift auxiliary panel from auxiliary panel housing to gain access. (3) Disconnect connector P914A from fuel preheat switch, if equipped. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to connector J913-10. (6) Connect negative (-) probe of multimeter to connector P914A-2 and note reading on multimeter. (7) If continuity is not present, repair wire 3020 (para 2-40) or replace auxiliary panel cable assembly (all models except M1079 w/o winch) (para 7-49) or M1079 w/o winch auxiliary panel cable assembly (para 7-50). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector P913-11. (3) Connect negative (-) probe of multimeter to connector P914A-1 and note reading on multimeter. (4) If continuity is not present, repair wire 1908 (para 2-40) or replace auxiliary panel cable assembly (all models except M1079 w/o winch) (para 7-49) or M1079 w/o winch auxiliary panel cable assembly (para 7-50). (5) Connect connector P914A to fuel preheat switch, if equipped. (6) Position auxiliary panel housing on auxiliary panel with six screws. (7) Tighten six screws to 24 lb-in. (3 N·m). (8) Connect connector P913 to connector J913. (9) Install personnel heater (para 18-9).