TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 627 of 1760
TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-387 2-387 2-387 2-387 2-387 CONTINUITY TEST (1) Remove instrument panel assembly for access (para 7-15). (2) Disconnect connector PX15 from main light switch. (3) Set multimeter to ohms. (4) Position main light switch to SER DRIVE (TM 9-2320-365-10). (5) Position main light switch auxiliary lever to PANEL BRT (TM 9-2320-365-10). (6) Connect positive (+) probe of multimeter to main light switch terminal F. (7) Connect negative (-) probe of multimeter to main light switch terminal B and note reading on multimeter. (8) If continuity is not present, replace main light switch (para 7-17). (9) Position main light switch to OFF (TM 9-2320-365-10).