TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 604 of 1760
KNOWN INFO 2. TEST OPTIONS REASON FOR QUESTION YES NO WARNING CAUTION Read WARNING and CAUTION on following page. Voltage Test or STE/ICE-R Test #89 POSSIBLE PROBLEMS e18D. VOLTS GAGE DOES NOT ILLUMINATE (CONT) WATER TEMP gage illuminates. Faulty dashboard cable assembly. Faulty VOLTS gage. Is 12 VDC present at connector PX10 socket 2? If 12 VDC is not present, wire 1908 is faulty. If 12 VDC is present, VOLTS gage is faulty. Replace VOLTS gage (para 7-14). Repair wire 1908 from connector PX10 socket 2 to connector PX11 socket 2 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). TM 9-2320-365-20-1 2-380.16 Change 1