TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 585 of 1760
CAUTION  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  CONTINUITY TEST  Change 1 2-377  TM 9-2320-365-20-1  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector PX17A socket 2.  (3) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (4) If continuity is not present, repair wire 3020  from connector PX17A socket 2 to  connector PX12A socket 2 (para 2-40) or  replace WTEC II dashboard cable assembly  (para 7-10) or WTEC III dashboard cable  assembly (para 7-11).  (5) If continuity is present, repair wire 1908  from connector PX17A socket 1 to  connector PX6 socket 2 (para 2-40) or  replace WTEC II dashboard cable assembly  (para 7-10) or WTEC III dashboard cable  assembly (para 7-11).  (6) Connect connector PX17A to master power  switch lamp base connector.  (7) Install instrument panel assembly (para  7-15).