TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 555 of 1760
CAUTION  CONTINUITY TEST  CONTINUITY TEST  Inspect connector pins/sockets for damage,  corrosion, and serviceability. Check that  connector pins are not pushed back and  are capable of making good contact.  NOTE  Use care when testing electrical connectors.  Do not damage connector pins or sockets  with multimeter probes. Failure to comply  may result in damage to equipment.  Change 1 2-369  TM 9-2320-365-20-1  (1) Disconnect connector P921 from connector  J921.  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter to  connector P921 pin A.  (4) Connect negative (-) probe of multimeter to  connector J39 pin 2 and note reading on  multimeter.  (5) If continuity is not present, repair wire 3028  in troop transport alarm cable assembly  (para 2-40) or replace troop transport alarm  cable assembly (para 20-79).  (1) Set multimeter to ohms.  (2) Connect positive (+) probe of multimeter to  connector J39 socket 1.  (3) Connect negative (-) probe of multimeter to  connector P921 pin C and note reading on  multimeter.  (4) If continuity is not present, repair wire 3028  in troop transport alarm cable assembly  (para 2-40) or replace troop transport alarm  cable assembly (para 20-79).  (5) Connect connector P39 to connector J39.  (6) Connect connector clamp on connector P39.  (7) Lower cab (TM 9-2320-365-10).