TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 521 of 1760

CAUTION Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX10 socket 1. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 3004 from connector PX10 socket 1 to terminal board TB2 position 9 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly para 7-11). (5) If continuity is present, replace VOLTS gage (para 7-14). (6) Connect connector PX10 to VOLTS gage connector. (7) Connect connector clamp on VOLTS gage connector. (8) Install instrument panel assembly (para 7-15). CONTINUITY TEST Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. NOTE Change 1 2-346.3 TM 9-2320-365-20-1