TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 493 of 1760

RESISTANCE TEST RESISTANCE TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX6 pin 4. (3) Connect negative (-) probe of multimeter to known good ground and note reading on multimeter. (4) If 202-243 ohms resistance is not present, go to step 4 of this fault. (1) Start engine (TM 9-2320-365-10). (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to connector PX6 pin 4. (4) Connect negative (-) probe of multimeter to known good ground and note reading on multimeter. (5) If 90-130 ohms resistance is not present, replace engine oil pressure transmitter (para 7-41). (6) If 90-130 ohms resistance is present, replace engine OIL PRESS gage (para 7-14). (7) Shut down engine (TM 9-2320-365-10). (8) Connect connector PX6 to engine OIL PRESS gage connector. (9) Connect connector clamp to engine OIL PRESS gage connector. (10) Install instrument panel assembly (para 7-15). TM 9-2320-365-20-1 Change 2 2-328.1