TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 464 of 1760

KNOWN INFO POSSIBLE PROBLEMS Lighted indicator display OK. WATER TEMP gage illuminates. WATER TEMP gage OK. WATER TEMP gage sensor OK. Faulty dashboard cable assembly. Faulty engine control cable assembly. 4. TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION If continuity is not present, wire 33 in dashboard cable assembly is faulty. If continuity is present, wire 33 in engine control cable assembly is faulty. NO CAUTION Read CAUTION on following page. Is continuity present from connector PX11 pin 4 to connector J31 pin 20? Repair wire 33 from connector P31 socket 20 to connector P41 (para 2-40) or replace engine control cable assembly (para 7-72). YES Repair wire 33 from connector PX11 pin 4 to connector J31 pin 20 (para 2-40). or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para7-11). e8. WATER TEMP GAGE DOES NOT OPERATE OR IS INACCURATE (CONT) TM 9-2320-365-20-1 2-316.4 Change 1