TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 463 of 1760
CONTINUITY TEST (1) Raise cab (TM 9-2320-365-10). (2) Disconnect connector clamp from WATER TEMP gage sensor connector, if equipped. (3) Disconnect connector P41 from WATER TEMP gage sensor connector. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to connector PX11 pin 4. (6) Connect negative (-) probe of multimeter to connector P41 and note reading on multimeter. (7) If continuity is not present, go to step 4 of this fault. (8) If continuity is present, replace WATER TEMP gage sensor (para 7-42). (9) Connect connector P41 to WATER TEMP gage sensor connector. (10) Connect connector clamp to WATER TEMP gage sensor connector, if equipped. (11) Lower cab (TM 9-2320-365-10). Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. NOTE Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION Change 1 2-316.3 TM 9-2320-365-20-1