TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 461 of 1760
RESISTANCE TEST CAUTION Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back and are capable of making good contact. TM 9-2320-365-20-1 Change 1 2-316.1 (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX11 pin 4. (3) Connect negative (-) probe of multimeter to a known good ground and note reading on multimeter. (4) If less than 750 ohms is present, go to step 3 of this fault. (5) If greater than 750 ohms is present, replace WATER TEMP gage (para 7-14).