KNOWN INFO 1. REASON FOR QUESTION Voltage Test or STE/ICE-R Test #89 TEST OPTIONS CAUTION WARNING Read WARNING and CAUTION on following page. START NO Lighted indicator display OK. WATER TEMP gage illuminates. POSSIBLE PROBLEMS Is 24 vdc present on connector PX11 pin 3? Faulty dashboard cable assembly. Faulty WATER TEMP gage. Faulty engine control cable assembly. Faulty WATER TEMP gage sensor. If 24 vdc is not present, wire 1546 is faulty. YES e8. WATER TEMP GAGE DOES NOT OPERATE OR IS INACCURATE INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-365-10). Personnel Required (2) References TM 9-4910-571-12&P Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) Materials/Parts Wire, Elect, 50 ft (Item 77, Appendix D) Repair wire 1546 from connector PX11 pin 3 to terminal board TB1 position 61 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). TM 9-2320-365-20-1 2-314 Change 1