KNOWN INFO POSSIBLE PROBLEMS YES 2. NO TEST OPTIONS Resistance Test or STE/ICE-R Test #91 REASON FOR QUESTION CAUTION Read CAUTION on following page. KNOWN INFO POSSIBLE PROBLEMS 3. YES Go to step 5 of this fault. TEST OPTIONS Continuity Test or STE/ICE-R Test #91 REASON FOR QUESTION NO CAUTION Read CAUTION on following page. Lighted indicator display OK. FUEL gage illuminates. Faulty FUEL gage. Faulty dashboard cable assembly. Faulty start and charging cable assembly. Faulty fuel level sensor. Replace FUEL gage (para 7-14). If greater than 30 ohms is present, FUEL gage is faulty. Is less than 30 ohms present from connector PX9 pin 4 to a known good ground? e7. FUEL GAGE DOES NOT OPERATE OR IS INACCURATE (CONT) TM 9-2320-365-20-1 2-310 Change 1 Lighted indicator display OK. FUEL gage illuminates. FUEL gage OK. Faulty dashboard cable assembly. Faulty start and charging cable assembly. Faulty fuel level sensor. Is continuity present from connector PX9 pin 4 to connector P82 pin 1? If continuity is not present, wire 28 is faulty.