TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 435 of 1760

CONTINUITY TEST CAUTION (10) Connect batteries (para 7-48). (11) Raise spare tire (TM 9-2320-365-10). TM 9-2320-365-20-1 Change 1 2-275/(2-276 Blank) All data on pages 2-276 thru 2-299, including pages 2-277 thru 2-298, deleted. (1) Set multimeter to ohms. When testing to terminal X1 on PDP, ensure that multimeter probes come in contact with the outside metal ring. Failure to comply may result in false troubleshooting test results. (2) Connect positive (+) probe of multimeter to terminal X1 on PDP. (3) Connect negative (-) probe of multimeter to terminal lug TL44 and note reading on multimeter. (4) If continuity is not present, replace 200 AMP terminal block to PDP 24 VDC cable (para 20-68). (5) If continuity is present, replace 200 AMP reverse polarity relay (para 20-58). (6) Position terminal lug TL44 on left 24V LOAD terminal stud on 200 AMP terminal block with washer, lockwasher, and nut. (7) Tighten nut to 15-19 lb-ft (21-25 N.m) (8) Position dust boot on left 24V LOAD terminal stud on 200 AMP terminal block. (9) Install PDP cover (para 16-2).