TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 427 of 1760

CONTINUITY TEST (1) Lift dust boot from left 24V LOAD terminal stud on 200 AMP terminal block. (2) Remove nut, lockwasher, washer, and terminal lug TL44 from left 24V LOAD terminal stud on 200 AMP terminal block. Discard lockwasher. (3) Remove nut, lockwasher, washer, and terminal lug TL167 from right 24V LOAD terminal stud on 200 AMP terminal block. Discard lockwasher. (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to left 24V LOAD terminal stud on 200 AMP terminal block. (6) Connect negative (-) probe of multimeter to right 24V LOAD terminal stud on 200 AMP terminal block and note reading on multimeter. (7) If continuity is not present, replace 200 AMP terminal block (para 20-69). Change 1 2-274.17 TM 9-2320-365-20-1