CONTINUITY TEST  (1) Remove circuit breaker CB36 from PDP.  (2) Set multimeter to ohms.  (3) Connect positive (+) probe of multimeter  to relay K2 socket 87 on PDP.  (4) Connect negative (-) probe of multimeter to  circuit breaker CB36 socket 6 on PDP and  note reading on multimeter.  (5) If continuity is not present, repair wire  1604 from relay K2 socket 87 on PDP to  bus bar X6 on PDP (para 2-40) or replace  WTEC II dashboard cable assembly (para  7-10) or WTEC III dashboard cable  assembly (para 7-11).  (6) If continuity is present, replace bus bar X6  on PDP or replace WTEC II dashboard  cable assembly (para 7-10) or WTEC III  dashboard cable assembly (para 7-11).  (7) Install circuit breaker CB36 in PDP.  (8) Install relay K2 in PDP.  (9) Install power distribution panel (PDP) cover  (para 16-2).  (10) Connect batteries (para 7-48).  Change 1 2-274.1  TM 9-2320-365-20-1