KNOWN INFO TEST OPTIONS  REASON FOR QUESTION  5.  e4. 24 VDC CIRCUITS DO NOT OPERATE (CONT)  NO  Go to step 14 of this fault. YES  Continuity Test or  STE/ICE-R Test #91  This question eliminates  possible problems and  determines where  troubleshooting continues.  Service drive lights OK.  Circuit breaker CB70 OK.  Batteries OK.  100 AMP reverse polarity relay  OK.  100 AMP reverse polarity relay  to power distribution panel  (PDP) 24 VDC cable OK.  Battery to 100 AMP reverse  polarity relay 24 VDC cable  OK.  200 AMP reverse polarity  relay OK.  200 AMP terminal block OK.  Battery to 200 AMP terminal  block 24 VDC cable  assembly OK.  200 AMP terminal block to  reverse polarity relay 24  VDC battery cable OK.  200 AMP terminal block to  reverse polarity relay 24  VDC load cable OK.  200 AMP terminal block to  power distribution panel  (PDP) 24 VDC cable OK.  POSSIBLE PROBLEMS  Faulty relay K2.  Faulty master power switch.  Faulty dashboard cable  assembly.  Is continuity present from  relay K2 socket 86 on PDP  to circuit breaker CB70  socket 3 on PDP?  TM 9-2320-365-20-1  2-266 Change 1