TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 387 of 1760
CONTINUITY TEST CAUTION (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to terminal lug TL80. When testing to terminal X2 on PDP, ensure that multimeter probes come in contact with the outside metal ring. Failure to comply may result in false troubleshooting test results. (3) Connect negative (-) probe of multimeter to terminal block X2 on PDP and note reading on multimeter. (4) If continuity is not present, replace 200 AMP terminal block to PDP 12 VDC cable (para 20-65). (5) Position terminal lug TL80 on left 12V LOAD terminal stud on 200 AMP terminal block with washer, lockwasher, and nut. (6) Tighten nut to 15-19 lb-ft (21-25 N.m). (7) Position dust boot on left 12V LOAD terminal stud on 200 AMP terminal block. Change 1 2-256.29 TM 9-2320-365-20-1