CONTINUITY TEST (1) Lift terminal cover on 12V BAT terminal stud on 100 AMP reverse polarity relay. (2) Remove nut, lockwasher, terminal lug TL61, and terminal lug TL47 from 12V BAT terminal stud on 100 AMP reverse polarity relay. Discard lockwasher. (3) Set multimeter to ohms. (4) Connect positive probe (+) of multimeter to terminal lug TL99. (5) Connect negative probe (-) of multimeter to terminal lug TL47 and note reading on multimeter. (6) If continuity is not present, replace battery to 100 AMP reverse polarity relay 12 VDC cable (para 7-67). (7) If continuity is present, replace 100 AMP reverse polarity relay (para 7-27). (8) Lift terminal cover on 12V BAT terminal stud on 100 AMP reverse polarity relay. (9) Position terminal lugs TL47 and TL61 on 12V BAT terminal stud on 100 AMP reverse polarity relay with lockwasher and nut. Change 1 2-256.23 TM 9-2320-365-20-1 (10) Tighten nut to 120-144 lb-in. (14-16 N.m). (11) Position air hose on intake air cleaner boot with clamp. (12) Tighten clamp to 36-48 lb-in. (4-5 N.m). (13) Connect batteries (para 7-48). (14) Raise spare tire (TM 9-2320-365-10).