TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 375 of 1760
CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to terminal lug TL52. (3) Connect negative (-) probe of multimeter to terminal lug TL48 and note reading on multimeter. (4) If continuity is not present, replace battery to shunt cable assembly (para 7-69) . (5) If continuity is present, replace starter to chassis ground cable (para 7-83). (6) Install terminal lug TL52 on shunt with lockwasher and screw. (7) Position air hose on intake air cleaner boot with clamp. (8) Tighten clamp to 36-48 lb-in. (4-5 N.m). (9) Raise spare tire (TM 9-2320-365-10). (10) Connect batteries (para 7-48). Change 1 2-256.17 TM 9-2320-365-20-1