CONTINUITY TEST NOTE (1) Raise cab (TM 9-2320-365-10). (2) Lower spare tire (TM 9-2320-365-10). (3) Install PDP cover (para 16-2). (4) Loosen clamp on air hose. (5) Remove air hose from intake air cleaner boot. Tag wires and connection points prior to disconnecting. (6) Remove screw, lockwasher, and terminal lug TL52 from shunt. Discard lockwasher. (7) Remove screw, lockwasher, and terminal lug TL45 from shunt. Discard lockwasher. (8) Set multimeter to ohms. (9) Connect positive (+) probe of multimeter to one end of shunt. (10) Connect negative (-) probe of multimeter to other end of shunt and note reading of multimeter. (11) If continuity is not present, replace shunt (para 7-26). TM 9-2320-365-20-1 Change 1 2-256.13