TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 363 of 1760
VOLTAGE TEST WARNING Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuits and cause severe burns or electrical shock. CAUTION (1) Connect batteries (para 7-48). (2) Set multimeter to volts DC. When testing to terminal X2 on PDP, ensure that multimeter probes come in contact with the outside metal ring. Failure to comply may result in false troubleshooting test results. (3) Connect positive (+) probe of multimeter to terminal X2 on PDP (4) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (5) If 12 VDC is not present, go to step 11 of this fault. Change 1 2-256.5 TM 9-2320-365-20-1