Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back or not capable of making good contact. CONTINUITY TEST Change 1 2-251 TM 9-2320-365-20-1 (1) Disconnect connector clamp from connector P116. (2) Disconnect connector P116 from WTEC III transmission ECU connector. (3) Set multimeter to ohms. (4) For each line of Table 2-8.3. Connector PX33 Ground Continuity Test perform the following: (a) Connect positive (+) probe of multimeter to connector PX33 socket. (b) Connect negative (-) probe of multimeter to connector P116 position and not reading on multimeter. (5) If continuity is not present on either wire in Table 2-8.3. Connector PX33 Continuity Test repair wire (para 2-40) or replace WTEC III dashboard cable assembly (para 7-11). (6) Install PDP on dashboard with three screws. (7) Connect connector P116 to WTEC III transmission ECU connector. (8) Connect connector clamp to connector P116. Connector PX33 Socket Connector P116 Socket Wire Table 2-8.3. Connector PX33 Continuity Test P L A B C D E S M N R 32 15 5 6 7 8 9 14 10 3 16 143 176 170 171 172 173 174 180 175 124 136