Use care when testing electrical connectors. Do not damage connector pins or sockets with multimeter probes. Failure to comply may result in damage to equipment. CAUTION NOTE Inspect connector pins/sockets for damage, corrosion, and serviceability. Check that connector pins are not pushed back or not capable of making good contact. CONTINUITY TEST (1) Disconnect batteries (para 7-48). (2) Remove kick panel (para 16-3). (3) Disconnect connector clamp from connector P115. (4) Disconnect connector P115 from WTEC III transmission ECU connector. (5) Set multimeter to ohms. (6) Connect positive (+) probe of multimeter to relay K26 socket 86. (7) Connect negative (-) probe of multimeter to connector P115 socket 8 and note reading on multimeter. (8) If continuity is not present, repair wire 123 from relay K26 socket 86 to connector P115 socket 8 (para 2-40) or replace WTEC III dashboard cable assembly (para 7-11). (9) Connect connector P115 to WTEC III transmission ECU connector. (10) Connect connector clamp to connector P115. (11) Install relay K26 in PDP. Change 1 2-247 TM 9-2320-365-20-1