TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 301 of 1760

CONTINUITY TEST (1) Disconnect batteries (para 7-48). (2) Remove relay K11 from PDP. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to relay K24 socket 86 on PDP. (5) Connect negative (-) probe of multimeter to relay K11 socket 30 and note reading on multimeter. (6) If continuity is not present, repair wire 1658 from relay K24 socket 86 on PDP to relay K30 socket 30 on PDP (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10) or WTEC III dashboard cable assembly (para 7-11). (7) Install relay K24 in PDP. Change 1 2-199 TM 9-2320-365-20-1