TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 297 of 1760
VOLTAGE TEST WARNING Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuits and cause severe burns or electrical shock. (1) Install relay K24 in PDP. (2) Disconnect batteries (para 7-48). (3) Remove relay K1 from PDP. (4) Connect batteries (para 7-48). (5) Set multimeter to volts DC. (6) Connect positive (+) probe of multimeter to relay K1 socket 86 on PDP. (7) Connect negative (-) probe of multimeter to ground. (8) Position master power switch to on (TM 9-2320-365-10) and note reading on multimeter. (9) If 24 VDC is not present, go to step 29 of this fault. (10) Position master power switch to off (TM 9-2320-365-10). Change 1 2-195 TM 9-2320-365-20-1