TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 279 of 1760
WARNING Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuits and cause severe burns or electrical shock. VOLTAGE TEST (1) Set multimeter to volts DC. (2) Connect positive (+) probe of multimeter to relay K24 socket 86 on PDP. (3) Connect negative (-) probe of multimeter to ground. (4) Position master power switch to on (TM 9-2320-365-10) and note reading on multimeter. (5) If 24 VDC is not present, go to step 23 of this fault. (6) Position master power switch to off (TM 9-2320-365-10). TM 9-2320-365-20-1 Change 1 2-177