CONTINUITY TEST  (1) Disconnect batteries (para 7-48).  (2) Remove nut, lockwasher, and terminal lug  TL23 from auxiliary starter solenoid.  Discard lockwasher.  (3) Set multimeter to ohms.  (4) Connect positive (+) probe of multimeter to  terminal lug TL23.  (5) Connect negative (-) probe of multimeter to  ground and note reading on multimeter.  (6) If continuity is not present, repair wire 93  from terminal lug TL23 to terminal lug TL25  (para 2-40) or replace start and charging  cable assembly (para 7-82).  (7) Install terminal lug TL23 on auxiliary starter  solenoid with lockwasher and nut.  Change 1 2-165  TM 9-2320-365-20-1