TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 265 of 1760

VOLTAGE TEST WARNING Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuits and cause severe burns or electrical shock. (1) Set multimeter to volts DC. (2) Connect positive (+) probe of multimeter to terminal lug TL33. (3) Connect negative (-) probe of multimeter to ground. (4) Lower cab (TM 9-2320-365-10). (5) Position master power switch to on (TM 9-2320-365-10). (6) Press starter pushbutton (TM 9-2320-365-10) and note reading on multimeter. (7) If 24 VDC is not present, go to step 9 of this fault. (8) Position master power switch to off (TM 9-2320-365-10). (9) Raise cab (TM 9-2320-365-10). Change 1 2-163 TM 9-2320-365-20-1