e1. CIRCUIT BREAKER DOES NOT OPERATE KNOWN INFO TEST OPTIONS REASON FOR QUESTION Nothing. POSSIBLE PROBLEMS Faulty circuit breaker. Continuity Test or STE/ICE-R Test #91 1. WARNING Read WARNING on following page. START INITIAL SETUP Equipment Conditions Engine shut down (TM 9-2320-365-10). References TM 9-4910-571-12&P Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) Replace circuit breaker (para 7-9). YES NO If continuity is not present, circuit breaker is faulty. Circuit breaker is OK. Return to troubleshooting for affected circuit. TM 9-2320-365-20-1 2-150 Change 1 Is continuity present through circuit breaker (refer to Table 2-8. Function To Circuit Breaker Cross Reference or Table 2-8.1. Circuit Breaker to Function Cross Reference)?