TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 201 of 1760

TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-109 2-109 2-109 2-109 2-109 WARNING Starting fluid is toxic and highly flammable. Container is pressurized. NEVER heat container and NEVER discharge starting fluid in confined areas or near open flame. Failure to comply may result in serious injury or death to personnel. NOTE Temperature at engine block must be below 100° F (38° C) before ether starting aid will work. ETHER CYLINDER INSPECTION ETHER VALVE TEST (1) Position master power switch to on (TM 9-2320-365-10). (2) Press ether start switch (TM 9-2320-365-10) and listen for ether valve to click. (3) Position master power switch to off (TM 9-2320-365-10). (1) Remove ether cylinder (para 4-15). (2) Shake ether cylinder to determine if ether is present. (3) Check ether cylinder for damage. (4) Install ether cylinder (para 4-15).