TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 1502 of 1760
TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-1076 2-1076 2-1076 2-1076 2-1076 1. START YES WARNING Read WARNING on following page. NO KNOWN INFO TEST OPTIONS REASON FOR QUESTION POSSIBLE PROBLEMS Faulty air dryer. Faulty dashboard cable assembly. Faulty start and charging cable assembly. Is 24 vdc present on connector P80-2? Go to step 3 of this fault. This question eliminates possible problems and determines where troubleshooting continues. Voltage Test or STE/ICE-R #89 Air hoses and fittings OK. Air compressor governor OK. e97. AIR DRYER DOES NOT OPERATE INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-365-10). Personnel Required (2) Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) References TM 9-4910-571-12&P