TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-1047 2-1047 2-1047 2-1047 2-1047 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector J93-2. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 3014 (para 2-40) or replace start and charging cable assembly (para 7-82). (5) If continuity is present, replace ether valve (para 4-15). (6) Raise spare tire (TM 9-2320-365-10). (1) Remove instrument panel assembly for access (para 7-15). (2) Disconnect connector PX13 from ether start switch. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to ether start switch terminal 1. (5) Connect negative (-) probe of multimeter to ether start switch terminal 3. (6) Position ether start switch to on (TM 9-2320-365-10) and note reading on multimeter. (7) If continuity is not present, replace ether start switch (para 7-18).