TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 1463 of 1760
TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1  2-1037 2-1037 2-1037 2-1037 2-1037  VOLTAGE TEST  Remove rings, bracelets, watches,  necklaces, and any other jewelry  before working around vehicle.  Jewelry can catch on equipment  and cause injury or short across  electrical circuit and cause severe  burns or electrical shock.  WARNING  (1) Remove kick panel (para 16-3).  (2) Remove three screws and washers from PDP.  (3) Remove three screws from PDP.  (4) Lift PDP outward to gain access.  (5) Disconnect wire 1807 from terminal board TB1  terminal 38.  (6) Disconnect connector PX34 from fan solenoid  JX34.  (7) Set multimeter to volts dc.  (8) Connect positive (+) probe of multimeter to  connector PX34-1.  (9) Connect negative (-) probe of multimeter to  ground.  (10) Position master power switch to on  (TM 9-2320-365-10).  (11) Position radiator fan off switch to on  (TM 9-2320-365-10) and note reading on  multimeter.  (12) If 24 vdc is not present, go to step 4 of this  fault.  (13) Position radiator fan off switch to off  (TM 9-2320-365-10).  (14) Position master power switch to off  (TM 9-2320-365-10).  (15) Connect wire 1807 to terminal board TB1  terminal 38.