TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 1451 of 1760

TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 TM 9-2320-365-20-1 2-1025 2-1025 2-1025 2-1025 2-1025 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector J7-1. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 1426 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10). (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector J7-2. (3) Connect negative (-) probe of multimeter to ground and note reading on multimeter. (4) If continuity is not present, repair wire 1408 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10).