TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 1431 of 1760

(1) Disconnect batteries (para 7-48). (2) Remove power distribution panel (PDP) cover (para 16-2). (3) Remove relay K11 from power distribution panel (PDP). (4) Set multimeter to ohms. (5) Connect positive (+) probe of multimeter to relay K11 terminal 30. (6) Connect negative (-) probe of multimeter to relay K11 terminal 87A and note reading on multimeter. (7) If continuity is not present, replace relay K11 (para 7-9). CONTINUITY TEST Change 1 2-1015 TM 9-2320-365-20-1