TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download

Page 1413 of 1760

TM 9-2320-365-20-1 Change 2 2-997 (1) Remove WTEC III relay K37 from PDP. (2) Set multimeter to ohms. (3) Connect positive (+) probe of multimeter to connector J913-15. (4) Connect negative (-) probe of multimeter to PDP, terminal 30, where WTEC III relay K37 was removed, and note reading on multimeter. (5) If continuity is not present, repair wire 1904 (para 2-40) or replace WTEC III dashboard cable assembly (para 7-11). (6) Install WTEC III relay K37 in PDP. CONTINUITY TEST