TM 9-2320-365-20-1 Change 2 2-989 CONTINUITY TEST CONTINUITY TEST (1) Set multimeter to ohms. (2) Connect positive (+) probe of multimeter to connector PX33-E2. (3) Connect negative (-) probe of multimeter to connector J913-14 and note reading on multimeter. (4) If continuity is not present, repair wire 2019 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10). (5) Connect connector PX33 to WTEC II VIM. (6) Tighten screw in connector PX33. (1) Loosen screw in connector PX33. (2) Disconnect connector PX33 from WTEC II VIM. (3) Set multimeter to ohms. (4) Connect positive (+) probe of multimeter to connector J913-15. (5) Connect negative (-) probe of multimeter to connector PX33-E3 and note reading on multimeter. (6) If continuity is not present, repair wire 1904 (para 2-40) or replace WTEC II dashboard cable assembly (para 7-10).