TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 1391 of 1760
TM 9-2320-365-20-1 VOLTAGE TEST Remove rings, bracelets, watches, necklaces, and any other jewelry before working around vehicle. Jewelry can catch on equipment and cause injury or short across electrical circuits and cause severe burns or electrical shock. WARNING Change 2 2-975 (1) Remove six screws from auxiliary panel. (2) Lift auxiliary panel from auxiliary panel housing to gain access. (3) Disconnect connector P904 from PTO switch. (4) Set multimeter to volts DC. (5) Connect positive (+) probe of multimeter to connector P904-5. (6) Connect negative (-) probe of multimeter to ground. (7) Position master power switch to on (TM 9-2320-365-10) and note reading on multimeter. (8) If 24 VDC is not present, repair wire 1925 (para 2-40) or replace auxiliary panel cable assembly (all models except M1079 w/o winch) (para 7-49). (9) Position master power switch to off (TM 9-2320-365-10).