TM 9-2320-365-20-1 KNOWN INFO YES NO TEST OPTIONS REASON FOR QUESTION e87. 11K SELF-RECOVERY WINCH DOES NOT PAY OUT (CONT) POSSIBLE PROBLEMS Continuity Test or STE/ICE-R Test #91 Is continuity present between connector P903-7 and connector P210-8? 2-964 Change 2 4. Circuit breaker OK. 11K self-recovery winch reels in OK. Winch control valve assembly OK. WINCH IN/OUT switch OK. Faulty winch control valve cable assembly. Faulty PTO cable assembly. Faulty auxiliary panel cable assembly. If continuity is not present, wire 2008 is faulty. Repair wire 2008 (para 2-40) or replace auxiliary panel cable assembly (all models except M1079 w/o winch) (para 7-49).