TM-9-2320-365-20-1 LMTV Unit Maintenance Manual M1078 Series - Volume 1 Download
Page 1374 of 1760
e87. 11K SELF-RECOVERY WINCH DOES NOT PAY OUT  INITIAL SETUP  Equipment Condition  Engine shut down (TM 9-2320-365-10).  Personnel Required  (2)  References  TM 9-4910-571-12&P  Tools and Special Tools  Tool Kit, Genl Mech (Item 44, Appendix C)  STE/ICE-R (Item 39, Appendix C)  Multimeter, Digital (Item 22, Appendix C)  Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C)  Materials/Parts  Wire, Elect, 50 ft (Item 77, Appendix D)  KNOWN INFO  1.  Is 24 VDC present on winch  out solenoid L5 connector  terminal 1?  WARNING  Read WARNING  on following page.  START  YES  NO  Go to step 3 of this fault.  TEST OPTIONS  Voltage Test or  STE/ICE-R Test #89  REASON FOR QUESTION  This question eliminates  possible problems and  determines where  troubleshooting continues.  TM 9-2320-365-20-1  2-958 Change 2  Circuit breaker OK.  11K self-recovery winch reels  in OK.  POSSIBLE PROBLEMS  Faulty winch control valve  cable assembly.  Faulty winch control valve  assembly.  Faulty WINCH IN/OUT switch.  Faulty PTO cable assembly.  Faulty auxiliary panel cable  assembly.