e87. 11K SELF-RECOVERY WINCH DOES NOT PAY OUT INITIAL SETUP Equipment Condition Engine shut down (TM 9-2320-365-10). Personnel Required (2) References TM 9-4910-571-12&P Tools and Special Tools Tool Kit, Genl Mech (Item 44, Appendix C) STE/ICE-R (Item 39, Appendix C) Multimeter, Digital (Item 22, Appendix C) Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C) Materials/Parts Wire, Elect, 50 ft (Item 77, Appendix D) KNOWN INFO 1. Is 24 VDC present on winch out solenoid L5 connector terminal 1? WARNING Read WARNING on following page. START YES NO Go to step 3 of this fault. TEST OPTIONS Voltage Test or STE/ICE-R Test #89 REASON FOR QUESTION This question eliminates possible problems and determines where troubleshooting continues. TM 9-2320-365-20-1 2-958 Change 2 Circuit breaker OK. 11K self-recovery winch reels in OK. POSSIBLE PROBLEMS Faulty winch control valve cable assembly. Faulty winch control valve assembly. Faulty WINCH IN/OUT switch. Faulty PTO cable assembly. Faulty auxiliary panel cable assembly.